KD-TS furnace pre-furnace silicon carbon analyzer
Key features:
It adopts anti-electromagnetic interference, dust insulation, portable design, and is easy to operate. Through the improved evaluation method, it can automatically control important metallurgical parameters, make up for the shortcomings of the "spectrum" that cannot accurately measure non-metallic elements (C, Si), and the conventional analytical instruments can not meet the time requirements of pre-furnace analysis and the quality control requirements of casting production.
Main parameters of KD-TS furnace pre-furnace carbon silicon analyzer:
1. Measurement function: thermal analysis of white iron, gray cast iron and ductile iron.
2. Measurement parameters: determine the tensile strength Rm and hardness HB of molten iron by measuring CEL, C, Si, TL, TS, △T and △TM
3. Temperature measurement range: 1250°C~1350°C
4. Measuring range: C: 2.1~4.2% Si: 0~5.0% CEL: 2.5~5.0%
5. Accuracy: ≤±1°C CEL±0.047% C±0.05% Si±0.1%
6. Display: 4-digit LED display word height 50mm resolution: 1 °C
7. Operation mode: 9 buttons to select the required parameters, in which "Auto" displays CEL, C, Si, and adjusts the C Si content through the potentiometer.
8. Working parameters: power supply AC 220V, 50Hz; The power is 30W, and the ambient temperature is 0~50°C
9. Temperature compensation range: 0~15°C
10. Matching sample cup type: K type
11. Display temperature unit: Fahrenheit or Celsius can be set
12. Measurement time: 240 seconds (generally 1 minute 45 seconds)
13. Measurement status display: "Ready" green light, "Measure" yellow light, "Complete" red light display on the instrument
Product consultation